Product Overview
HONEYWELL S8610 UNIVERSAL PROVEN PILOT SPARK CONTROL
Features
- Provide ignition sequences, flame monitoring and safety shutoff for intermittent pilot central furnaces and heating appliances.
- Functional equivalent of S86, S860, and S90 modules. Include spark cable adapter to allow field replacement of S86, S860, and S90 without replacing existing spark cable.
- Include relay contacts for use with any intermittent pilot gas control string with maximum 1.0A pilot and 2.0A main valve rating; Honeywell VR8204, VR8304, or VR8440 combination gas control recommended.
Specifications
- Electrical Ratings: 24 Vac
- Frequency: 60 Hz
- Flame Failure Response Time (sec): 2 seconds maximum
- PrePurge: None
- Ambient Temperature Range (F): -40 F to +175 F
- Ignition System Type: Intermittent Pilot
- Ignition Sequence: Continuous Retry
- Typical Gas Control: VR8204, VR8304
- Type of Gas: Natural or LP
- Flame Sense: Single Rod
- Ignition Source: Internal high voltage spark generator
- Ignition Trials To Lockout: continuous retry
- Lockout Timing: continuous retry
- Ignition Trial Time (sec): 90 sec
- Maximum Valve Load @ 24 Vac (Amps): 1A Pilot, 2A Main @ 24Vac
- Typical Ignition Hardware: Q345, Q3451, Q3452
- Between Trial Time (sec): 5 minute delay after failed trial for ignition.